2 16 bit dmx control, 16 bit dmx control – LSC Lighting GenVI User Manual

Page 18

Advertising
background image

Menu System

GenVI Dimmer

Operator Manual V1.0

Page 14


The menu shows the first 6 channels. Use the < or > buttons to see the other groups of 6
channels. Touch a channel to select it. You can select multiple channels. To select a range of
channels select your first channel then press Thru then your last channel. Use All to select
all channels. Press None to de-select all channels.
When you have selected your channel(s) press Set Address.

Enter the required DMX address then press Apply.
If more than one channel is selected, then the lowest channel number will be patched to the
selected DMX slot and the following dimmers will be patched to the sequential DMX slot
numbers.
For example, if channels 1, 2, 3 and 10 are selected and DMX slot number 24 is applied the
result will be ……

Channel DMX Slot

1

24

2

25

3

26

10

27


To patch multiple channels to the same DMX slot patch them one at a time.
When finished patching press Exit.
If dimmer channels have been individually patched, then the “DMX Address” home page
displays a table showing the patches. For example:

3.8.2

16 Bit DMX Control

The DMX512-A signal contains the level information for 512 DMX slots (addresses). The
level for each slot is sent in 8 bits of data which gives a maximum resolution of 256 discrete

Advertising