5.

Detection

Check

During the detection check, the following OSD

appears on the display and checks are made
to detect dark sound in the listening room,
whether there are speakers or not and polarity.

A U T O S E T U P

S P E A K E R S C H E C K : - -

N O W A N A L Y Z I N G ! !

C A N C E L

E X I T

Note:

• The detection check measures the state of use of all

speakers whether actually used or not.

For example, if the center speaker is not used, the

test tone will require time to go from the L-channel
to the R-channel, therefore be careful not to unplug
the microphone or operate the SR6001 during this
time.

6.

When the detection check ends, the following

OSD appears on the display.

A U T O S E T U P

S P E A K E R S C H E C K : O K

1 S T M I C P O S I T I O N ! !

S T A R T

C H E C K

E X I T

Here, to view the results of the detection check,

select “CHECK” with the

3/4 cursor buttons

and press the ENTER button. The results will
be displayed.

S P E A K E R C O N F I G
C H E C K ! ! S P E A K E R
F R O N T : Y E S
C E N T E R : N O N
F R O N T R : Y E S
S U R R . R : Y E S
S U R R . B R : N O N
S U R R . B L : N O N
S U R R . L : Y E S
S U B W : Y E S

R E T U R N

E X I T

If the check results indicate an error, take suitable
action with that item and remeasure. (For error
messages, see “ERROR MESSAGES” on
page 34.)

2-1 AUTO SETUP (MultEQ™ SETUP)

The AUTO SETUP (MultEQ™ Setup) feature of
the SR6001 measures sound characteristics of the
speaker system and room where the receiver is used
and automatically optimizes settings.

The Audyssey MultEQ™ technology adopted by the
SR6001 provides the best listening environment for
multiple listeners.
To do this, the AUTO SETUP feature measures a
test tone emitted by each channel in a maximum of 6
listening positions, using the supplied microphone.
The measurement results are analyzed using an
original algorithm and environmental settings are
made to improve the sound characteristics of the
listening area.

Note:

• A special microphone (ACM1, option) is needed

to use the Audyssey MultiEQ function. Contact a
Marantz Authorized Dealer or Customer Support
regarding purchase of this microphone.

To set up the speaker system (i.e., adjusting speaker
distance, etc.) without using the AUTO SETUP feature,
see “MANUAL SETUP” on page 35 of the manual.

HOW TO PERFORM AUTO SETUP
During measurement, the OSD menu displays the
condition, therefore turn power to the monitor on.

1.

Connect the supplied microphone to the MIC

jack on the SR6001.

AV SURROUND RECEIVER SR6001

POWER ON/STANDBY

PHONES

STANDBY

L

C

R

SL

S

SR

LFE

DIGITAL

SURROUND

DISP

MULTI

AUTO

TUNED

ST

SPKR A B

V-OFF

NIGHT

PEAK

ANALOG

DIGITAL

ATT

SLEEP

SURR

DIRECT

AUTO

DISC 6.1

MT X 6.1

PCM

AAC

AUX 1 INPUT

AUDIO

S-VIDEO

DIGITAL

VIDEO

L

R

DOWN

UP

VOLUME

ENTER

INPUT SELECTOR

HT-EQ

HT-EQ

READY

2.

Set the microphone in the listening position.

Notes:

• Measurement can be done in a maximum of 6

listening positions.

For the fi rst measurement, set the microphone in the

main listening position.

• Use a stand or tripod to position the microphone at

ear height in the listening position.

• Remove any obstructions between the speakers and

microphone.

• To use the internal subwoofer of the amp, set the

volume to the middle point and set the crossover
frequency to the highest.

• During measurement, step away from the microphone

and operate the SR6001 via the remote control unit
from a position that is out of the path of the speaker
sound.

• The test tone output from the speakers during

measurement is loud. Be mindful of neighbors and
watch out for small children.

3.

Either

press

the

MultEQ™ button on the

front panel of the SR6001 or select “2. SPKR
SETUP” from the MAIN MENU, select “AUTO
SETUP
” with the

3/4 cursor buttons, and press

the ENTER button to display the start screen.

4.

Select the number of channels for the surround

back speaker you are using.

For a 5.1 channel speaker system, select

“NON” (Surround Back speaker off). (To use
speaker C or multi speaker, select “NON”. See
page 24, 41.)

Select

START” with the

3/4 cursor buttons

and press the ENTER button to star t
measurement.

A U T O S E T U P

A U T O S E T U P : S T A R T

M A I N R O O M
S U R R B A C K :

2 C H

R E T U R N

E X I T

After confirming the check results, select

RETURN” with the

3/4 cursor buttons and

press the ENTER button to return to the OSD
menu.

At this point, you can select “EXIT” to end Auto

Setup and return to “2. SPKR SETUP”.

7.

Calibration

Check

A U T O S E T U P

S P E A K E R S C H E C K : O K

1 S T M I C P O S I T I O N ! !

S T A R T

C H E C K

E X I T

Select

START” with the

3/4 cursor buttons

and press the ENTER button to measure the
fi rst point (main listening position).

During measurement, the following OSD

appears on the display. At this point, you can
cancel measurement by selecting “CANCEL
with the

3/4 cursor buttons and pressing the

ENTER button.

A U T O S E T U P

N O W A N A L Y Z I N G ! !

C A N C E L

E X I T

When this measurement ends, the following

OSD appears on the display

A U T O S E T U P

S P E A K E R S C H E C K : O K

2 N D M I C P O S I T I O N ! !

S T A R T

C A L C U L A T E

E X I T