Microcom 428T User Manual

Page 227

Advertising
background image

428T Operator’s Manual - 880037-0141

13-7

^AB ^D

COMMAND

21

Software Bank Switch #1: A non-volatile command used to set the various

functions identified below.
^AB12345678


Position:

12

Enquiry Responses:

00 = Control Codes

10 = Text Equivalent

3

1 = Ignore Control Codes; 0 = Accept

4

1 = Odd Parity; 0 = Even Parity

5

1 = Disable Parity (NONE); 0 = Enable Parity

6

1 = Enable Echo; 0 = Disable

7

1 = 8 Data Bits; 0 = 7 Data Bits

8

1 = Enable XON/XOFF; 0 = Disable

22

Software Bank Switch #2: A non-volatile command used to set the various
functions identified below.
^AB12345678

Position:
1

1 = Enable Clear Text; 0 = Disable

2

1 = Enable >RESTARTED< Response; 0 = Disable

3

1 = Disable Button; 0 = Enable

4

1 = Enable Print Repetition; 0 = Enable Form Feed

5

1 = Use Saved Format File; 0 = ROM Format

678

Power-up / ROM Format Selection:

000 = No Power-up Format
001 = ROM or Saved Format File 1
010 = ROM or Saved Format File 2
011 = ROM or Saved Format File 3
100 = ROM or Saved Format File 4
101 = ROM or Saved Format File 5
110 = ROM or Saved Format File 6
111 = ROM or Saved Format File 7

23

Software Bank Switch #3: A non-volatile command used to set the various
functions identified below.
^AB12345678

Position:
1

1 = Disable Extended ASCII; 0 = Enable

2

1 = Active LOW for >INPUT1<; 0 = Active HIGH

3

1 = Send Enquiry Response after Print; 0 = Disable

4

1 = Active LOW for >INPUT2<; 0 = Active HIGH

5

1 = Disable use of | for control; 0 = Enable

6

1 = Disable use of ^ for control; 0 = Enable

7

1 = Enable Binary Compression; 0 = Disable

8

1 = Enable Detect Blackline on Power-up; 0 = Disable

Advertising