^A

^D

COMMAND

XX

42

Load Label Width in dots (LSX): The ^Axx specifies the value.


XX

43

Load Label Height in dots (LSY): The ^Axx specifies the value.


XX

44

Load the Web Size in dots (WEB): The ^Axx specifies the value.


XX

45

Load the Gap Size in dots (GAP): The ^Axx specifies the value.


XX

46

Load Print Speed: The ^Axx specifies the value. Uses the same values as
the DPS header value; 0 to 13.


XX

47

Load the Label Control Byte (LCB): The ^Axx specifies the value.


XX

48

Load the Number of Steps to Activate Gap Detector (AGD): The ^Axx
specifies the value in Dot Rows.


XX

49

Load the Number of Steps Past Gap (SPG): The ^Axx specifies the value in
Dot Rows.


XX

50

Load X Direction Offset (OFX): The ^Axx specifies the value.


XX

51

Load Y Direction Offset (OFY): The ^Axx specifies the value.


XX

54

Send Format from RAM to the Port: The ^Axx specifies the slot number
where the format file is stored in RAM. Valid values for Axx are A1 to A128.


XX

55

Select Default Power-up Format: Selects the ROM power-up format. The
^Axx selects from the available formats 1 through 8.


56

Select User Defined Layout: Signals the end of the label field definition.

57

Enter Label Format Mode: Instructs the printer that information for a format
is following the command.


XX

58

Process Format Saved in RAM: The ^Axx selects which stored format to
process (1-128). This command takes the selected format in RAM and makes
it into a label.


XX

59

Save Formats to RAM. (1 - 128)

60

Clears Command 61


XX

61

Mark Text Starting Position: The ^Axx designates which text field to start
entering new data.

62

Pre-Padded Text: This command is sent after the text that is to appear at the
beginning of each field.


Advertising