Microcom 412 User Manual

Page 48

Advertising
background image

Printer Commands

Chapter 5

412 Operators Manual

40

^A

^D

COMMAND

23

Change SW3: Software dip switch #3. Below is the ^AB sequence:

12345678
^ABxxxxxxxx

*******.

Detect Black Line On Power-up

******.Q

1=Enable Binary Compression, 0=Disable

*****.)Q

Always 0

****.))Q

Always 0

***.)))Q

Always 0

**.))))Q

1=Send Response After Print

**

0=No Response After Print

*.)))))Q

1=Invert >INPUT 1< Polarity, 0=Normal

.))))))Q

1=Disable Extended ASCII, 0=Enable

Position:

1

Extended ASCII: If enabled, characters over 7F hex will be processed.

2

Invert >INPUT 1< Polarity: The >INPUT 1< message is normally returned when
the associated reflective sensor detects a signal. The polarity of this signal
should be inverted when used as a stock level sensor. (This feature is currently
available only on the model 322M printer)

3

Response After Print: If enabled, an enquiry response will be sent back
through the first serial port after every print.

4

Always 0

5

Always 0

6

Always 0

7

Binary Compression: If enabled, the printer will accept downloaded binary
compressed font or graphic files and enquiry responses must be sent using the
five NULL character method.

8

Detect Black Line on Power-up: If this bit is set, the printer will automatically
run a few labels and correctly set the ^D91 value.