Function name:

802.1X State Setting

Function description:

This function is used to configure the global parameters for RADIUS authentication in
802.1X port security application.

Parameter description:

Radius Server:

RADIUS server IP address for authentication.

Default: 192.168.1.1

Port Number:

The port number to communicate with RADIUS server for the authentication service.
The valid value ranges 1-65535.

Default port number is 1812.

Secret Key:

The secret key between authentication server and authenticator. It is a string with the
length 1 – 31 characters. The character string may contain upper case, lower case and
0-9. It is character sense. It is not allowed for putting a blank between any two
characters.

Default: Radius