MICROSENS 8 Port Gigabit Ethernet Switch

User’s Manual

165



enable egress-rate

Syntax
:
enable egress-rate <range> <data_rate>
Description:
To set up the egress-rate of the port.
Argument:
<range>:syntax 1,5-7, available from 1 to 8
<data_rate>: 0-1000
Possible value:
<range>: 1 to 8
<data_rate>: 0-1000
Example:
MICROSENS(bandwidth)# enable egress-rate 1-8 200


enable ingress-rate

Syntax
:
enable ingress-rate <range> <data_rate>
Description:
To set up the Ingress-rate of the ports.
Argument:
<range>:syntax 1,5-7, available from 1 to 8
<data_rate>: 0-1000
Possible value:
<range>: 1 to 8
<data_rate>: 0-1000
Example:
MICROSENS(bandwidth)# enable ingress-rate 1-8 100



enable storm-rate

Syntax
:
enable storm-rate <range> <data_rate>
Description:
To set up the storm-rate of the ports.
Argument:
<range>:syntax 1,5-7, available from 1 to 8
<data_rate>: 0-1000
Possible value:
<range>: 1 to 8
<data_rate>: 0-1000
Example:
MICROSENS(bandwidth)# enable strom-rate 1-8 150