Microsens MS453522M User Manual
Page 155

MICROSENS 8 Port Gigabit Ethernet Switch
User’s Manual
150
Syntax:
set suppTimeout <port-range> <sec>
Description:
A timer used by the Backend Authentication state machine in order to determine timeout
conditions in the exchanges between the Authenticator and the Supplicant or Authentication
Server. The initial value of this timer is either suppTimeout or serverTimeout, as determined by
the operation of the Backend Authentication state machine.
Argument:
<port range> : syntax 1,5-7, available from 1 to 8
<sec> : timer , range 1-65535
Possible value:
<port range> : 1 to 8
<sec> : 1-65535, default is 30
Example:
MICROSENS(802.1X)# set suppTimeout 2 30
set txPeriod
Syntax:
set txPeriod <port-range> <sec>
Description:
A timer used by the Authenticator PAE state machine to determine when an EAPOL PDU is to be
transmitted
Argument:
<port range> : syntax 1,5-7, available from 1 to 8
<sec> : timer, range 1-65535
Possible value:
<port range> : 1 to 8
<sec> : 1-65535, default is 30
Example:
MICROSENS(802.1X)# set txPeriod 2 30
show mode
Syntax:
show mode
Description:
To display the mode of each port.
Argument:
None.
Possible value:
None.
Example:
MICROSENS(802.1X)# show mode
Port Mode
====== ============
1 Disable
2 Multi-host
3 Disable
4 Disable
5 Disable
6 Disable
:
:
: