background image

MICROSENS 8 Port Gigabit Ethernet Switch

User’s Manual

71

Default SNMP function : Enable

Default community name for GET: public

Default community name for SET: private

Default community name for Trap: public

Default Set function : Enable

Default trap host IP address: 0.0.0.0

Default port number :162

Trap:

In the switch, there are 6 trap hosts supported. Each of them has its own community
name and IP address; is user-definable. To set up a trap host means to create a trap
manager by assigning an IP address to host the trap message. In other words, the trap
host is a network management unit with SNMP manager receiving the trap message
from the managed switch with SNMP agent issuing the trap message. 6 trap hosts can
prevent the important trap message from losing.

For each public trap, the switch supports the trap event Cold Start, Warm Start, Link
Down, Link Up and Authentication Failure Trap. They can be enabled or disabled
individually. When enabled, the corresponded trap will actively send a trap message
to the trap host when a trap happens. If all public traps are disabled, no public trap
message will be sent. As to the Enterprise (no. 6) trap is classified as private trap,
which are listed in the Trap Alarm Configuration function folder.

Default for all public traps: Enable.

Fig. 3-24 Community and trap host setting