Microsens MS453522M User Manual
Page 222

MICROSENS 8 Port Gigabit Ethernet Switch
User’s Manual
217
show lacp-priority
Syntax:
show lacp-priority
Description:
To display the value of LACP Priority.
Argument:
None
Possible value:
None
Example:
MICROSENS(trunk)# show lacp-priority
LACP System Priority : 32768
show status
Syntax:
show status
Description:
To display the aggregator status and the settings of each port.
Argument:
None.
Possible value:
None.
Example:
MICROSENS(trunk)# show status
Trunk Port Setting
Trunk Port Status
------------------------------------------------------------------ ------------------------------------
port
Method
Group
Active LACP
Aggtregator
Status
====== ======== ======= ============= ============= ========
1
None
0
Active
1
---
2
None
0
Active
2
---
3
LACP
2
Active
3
---
4
None
0
Active
4
---
5
None
0
Active
5
---
6
None
0
Active
6
---
7
None
0
Active
7
---
8
None
0
Active
8
---