XG0514-150204

I-Series Indoor Gas Fireplace

Installation

Figure 14 Sec.4

Location of Door retainer tabs

Check that the door retainers are properly engaged. If they are

not the door relief system may not operate properly. This can

cause a risk of injury or improper operation of the appliance.

LP Conversion

The 34FID-L is available in Natural Gas or Liquid Propane versions.

Should you have a Natural Gas unit that you would like to burn

Propane with; you can purchase an optional LP conversion kit

and install it using the following steps. To convert the unit to LP,

the unit must be disconnected from any gas supply, disconnected

from any electrical supply and batteries and removed from any

installation cavity.
The 6 major items that need modification to convert a unit to LP
1). Variable regulator on the gas valve
2). The main burner orifice
3). The pilot burner orifice
4). Set minimum primary air tab
5). Label on the valve showing the new specifications
6). Gas fitter conversion label

Figure 15 Sec.4

LP conversion kit showing pilot orifice, main burner orifice,

LP stepper motor, zap strap and gas fitter conversion label.

Tools required
1). Torx T20 Screw Driver Bit
2). 3/8" Socket Driver
3). 5/32" Allen Key
4). Needle Nose Pliers or Small Flat Head Screw Driver

WARNING

When installing the fireplace - gas lines, fittings,

accessories or any other objects cannot impede the

proper movement of the door buckles.

Advertising