Pilot Maintenance / Replacement

We suggest throughout this manual that maintenance on this
product should be performed yearly. This is the best practice in
order to keep your fireplace insert running reliably for many years
to come. One of the items that should be inspected yearly and
may need service is the Pilot Burner Assembly. The Pilot Burner
Assembly is responsible for lighting the appliances and provides
the safety mechanism to ensure that the appliance performs
safely. In order to service the pilot, the Door, Burner Assembly,
Log set etc. must first be removed. There are specific sections in
the manual that cover those procedures. Replacing the pilot can
be performed with the following steps.

Figure 34 Sec.6

Pilot Replacement Kit shown

1). Disconnect Gas and Electrical Supply to the Appliance. You will
need to have the unit outside the install to access the Valve location.
If the unit has already been installed, see the sections on removing
the Faceplate Panels and Vent Connections.

2). Remove the Firebox Panels and Burner Assembly (see appropriate
sections)

3). Remove the 2 heat shields and insulation that cover the pilot
assembly.

Figure 35 Sec.6

4). Remove the screw securing the pilot wire cover and remove
pilot wire cover.

Figure 36 Sec.6

5). Remove the 2 screws securing the right side of the light reflector
and remove part.

Figure 37 Sec.6

6). Remove the 2 screws that secure the pilot assembly and ground
wire to the floor of the firebox.

Figure 38 Sec.6