Maintenance – Montigo 34FID - Linear User Manual

Page 50

Advertising
background image

Page 50

XG0514-150204

I-Series Indoor Gas Fireplace

Maintenance

12). Install both new Blowers. Secure the Wire Harness with the Zip
Straps shown in the 2 pictures below.

Figure 22 Sec.6

1

3). At this point, if you want to test the Blower operation, do so

with the Gas Supply turned off or disconnected. To test the Blower
operation, you will need to re-connect the electrical supply temporarily.
Disconnect the Electrical Supply after testing the Blowers.

Figure 23 Sec.6

14). Re-install the Outer Shell Rear panel.

15). You will need to replace the Flue Collar Plate Gasket prior to
re-installation into the cavity.

Figure 24 Sec.6

16). Replace the Flue Connector Plate Gasket.

17). Re-install the unit into the Cavity. See the section on Vent
Connections.

18). Re-install the Face Plate Panels. See the section on Setup.

19). Re-connect the Electrical Supply.