Installation – Montigo 34FID - Linear User Manual

Page 17

Advertising
background image

Page 17

XG0514-150204

I-Series Indoor Gas Fireplace

Installation

Figure 21 Sec.4

Figure 22 Sec.4

6). Unplug the cable that runs from the stepper motor to the control

board and remove it from in between the control board mounting

bracket and the fireplace.

Figure 23 Sec.4

7). Place the LP stepper motor onto the valve being extremely

careful that the orientation of the regulator is correct.

8). Reinstall the 2 screws supplied with the conversion kit to fasten

the stepper motor to the valve body.

Figure 24 Sec.4

9). Attach the label provided to the side of the valve body. This

label shows that the valve has been converted using SIT approved

components.

Figure 25 Sec.4

10). Run the cable from the stepper motor in between the control

mounting bracket and fireplace.

Figure 26 Sec.4

12). Plug the cable into the control board.