2 specifications, Specifications, 1 general specifications – Nevion FR-2RU-10-2 User Manual

Page 5: 2 front view, 3 rear view

Advertising
background image

FR-2RU-10-2

Rev. N

nevion.com | 5

2. Specifications

2.1 General specifications

AC Power:

PWR-AC15/15/5/5V
AC power supply module 100-260 VAC.

DC Power (optional):

PWR-DC15/15/5/5V
DC power supply module 36-72 VDC.

Redundant Power
(optional):

PWR-AC15/15/5/5V or
PWR-DC15/15/5/5V.

Dimensions:

483 x 88 x 178

mm (19”, 2RU).

Card slots:

10.

Power Supply slots
(reserved):

2.

Internal voltages:

+5V, -5V, +15V, -15V.

2.2 Front view

The front view of the sub-rack shows status LEDs for each module that is included in
the sub-rack + two green LEDs for the power supply modules.

Figure 1: LEDs in front of the Flashlink sub-rack.

The uppermost LED of each module card is a "general status" LED.

-

Green light means that the card is OK.

-

Red light means that the card is faulty.

-

No light means that the power is not switched on.

The meaning of each LED on the module cards is described in their respective
manuals.

2.3 Rear view

Figure 2 shows an example of a fully equipped Flashlink sub-rack, seen from the rear
side.
To the left is the connector module for the power supply delivered with the sub-rack.
The other connector modules are described in their respective user manuals.

Figure 2: Example of fully equipped Flashlink sub-rack.

Advertising