FR-2RU-10-2

Rev. N

nevion.com | 9

In case of power failure, pins 3 and 7 will be physically connected (low impedance),
otherwise the connection between pins 3 and 7 will be high impedance.

4.2 RS-422 connection

At the rear end of the sub-rack is an RS-422 bus. When used in combination with the
GYDA-SC Rack System Controller, up to 8 sub-racks can be controlled. On the rear
end of the sub-rack are DIP-switches where each sub-rack can be assigned its own
address (see figure 3).

The RS-422 interfaces are shown in figure 3.

4.2.1 Pin-out RS-422 (RJ45)


Pin #1

Rx A (+)

Pin #2

Rx B (-)

Pin #3

Tx A (+)

Pin #4

Reserved

Pin #5

Reserved

Pin #6

Tx B (-)

Pin #7

Not Connected

Pin #8

Not Connected

Figure 4: RS-422 pin-out.

4.2.2 Connecting several sub-racks together

Several sub-racks can be connected to each other through the RS-422 ports on the
rear of each sub-rack.

One GYDA-SC controller can control maximum 8 sub-racks.

You start with the sub-rack containing the GYDA-SC Rack System Controller, and use
1 RS-422 port to loop through to the next.

The last sub-rack connected must be terminated with 110

in order to ensure proper

operation. The other port of the rack containing the GYDA-SC controller must be left
open, and cannot be connected to other sub-racks.

Figure 5 shows an example of how to connect 8 sub-racks together as seen from the
rear end. By using the RS-422 interface at the GYDA-SC controller card, we control 8
sub-racks via one RS-422 bus.