2 Specifications
Electrical SDI input
Number of inputs
2
Connectors
75 Ohm BNC
Equalization
Automatic;
>300m @270Mbps w/Belden 8281, with BER < 10E-12
>130m @1485Mbps w/Belden 1694A, with BER < 10E-12
Input Return loss
Active input
>15dB, 5MHz -1.485GHz
Input Return loss
passive bypass
>15dB, 5MHz -742.5MHz
>10dB, 742.5MHz - 1.485GHz
Jitter tolerance
SD limit:
10Hz-1kHz: >1 UI
10kHz
– 5MHz: >0.2 UI
HD limit:
10Hz-100kHz: >1 UI
100kHz
–10MHz: >0.2 UI
Electrical Sync input
Connector
75 Ohm BNC
Format
Black & Burst, Tri-level
Input Return loss
>35dB @ < 10MHz,
30dB @ < 30MHz
Electrical SDI outputs
Number of outputs
4
Connectors
75 Ohm BNC
Return Loss O1, O2
Active output
>15dB, 5MHz -1.485GHz
Output Return loss O1, O2
Passive bypass
>15dB, 5MHz -742.5MHz
>10dB, 742.5MHz - 1.485GHz
Return loss !O1, !O2
>15dB, 5MHz -742.5MHz
>10dB, 742.5MHz - 1.485GHz
Output signal level
800mV +/- 10%
Output signal rise / fall time
20% - 80%
SD limit: [0.4ns
– 1.5ns]; <0.5ns rise/fall var.
HD limit: < 270ps, <100ps rise/fall var.
Amplitude overshoot
<10%
Output timing jitter
SD: <0.2 UI
HD: <1 UI
Output alignment jitter
SD: <0.15 UI
HD: <0.2 UI