Installation, Continued – Desa FPVF33NRA User Manual

Page 12

Advertising
background image

www.desatech.com

113109-01D

1

INSTALLATION

Continued

2. If using blower, install and properly ground

GA3555, three-prong 120 volt electrical
outlet, in fireplace. Follow instructions in-
cluded in kit (see Accessories, page 38).

3. Install gas piping to fireplace location. This

installation includes an approved flexible
gas line (if allowed by local codes) after the
equipment shutoff valve. The flexible gas
line must be the last item installed on the gas
piping. See Installing Gas Piping to Fireplace
Location,
page 13.

4. Carefully set fireplace in front of rough

opening with back of fireplace inside wall
opening.

5. Plug electrical cord into electrical outlet

installed in step .

6. Carefully insert fireplace into rough

opening.

7. Attach flexible gas line to gas supply.

See Connecting Fireplace to Gas Supply,
page 14.

8. Attach fireplace to wall studs using nails

or wood screws through holes in nailing
flange (see Figure 15).

9. Check all gas connections for leaks. See

Checking Gas Connections, page 15.

10. Install perimeter trim after final finishing

and/or painting of wall (see Figure 7,
page 9).

35

1

/

2

"

17

3

/

4

"

33"

Figure 16 - Rough Opening for Installing

in Wall

35

1

/

2

"

17

3

/

4

"

33"

Figure 13 - Rough Opening for Installing

in Wall

39

3

/

8

"

27

7

/

8

"

55

5

/

8

"

35

1

/

2

"

Figure 14 - Rough Opening for Installing

in Corner

Figure 15 - Attaching Fireplace to Wall

Studs

Nailing
Flanges

Nails or
Wood
Screws

Models FPVF33PRA and FPVF33NRA

WARNING: A qualified electri-

cian must connect electrical wiring

to duplex outlet for built-in instal-

lation. Follow all local codes.

1. Frame in rough opening. Use dimensions

shown in Figure 16 for the rough opening.

2. If using blower, install wiring and properly

ground the three-prong, 120 volt electrical
outlet in fireplace.

3. Before replacing bottom of firebox, install

duplex outlet to the right support bracket
in the bottom of firebox (see Figure 17,
page 13).

4. Route wires from electrical box through

smallest hole in outer casing using strain
relief fitting provided (see Figure 17,
page 13).

5. Connect wires from the electrical box to

duplex outlet. Match wire colors to those
indicated on duplex outlet. Be sure to
connect ground wire.

Advertising