Installation – Desa FPVF33NRA User Manual

Page 15

Advertising
background image

www.desatech.com

113109-01D

15

CAUTION: Use only new,

black iron or steel pipe. Inter-

nally-tinned copper tubing may

be used in certain areas. Check

your local codes. Use pipe of

1/2" diameter or greater to allow

proper gas volume to fireplace.

If pipe is too small, undue loss

of volume will occur.

Installation must include an equipment shutoff
valve, union and plugged 1/8" NPT tap. Locate
NPT tap within reach for test gauge hook up.
NPT tap must be upstream from fireplace (see
Figure ).
IMPORTANT: Install equipment shutoff valve
in an accessible location. The equipment
shutoff valve is for turning on or shutting off
the gas to the appliance.
Check your building codes for any special
requirements for locating equipment shutoff
valve to fireplaces.
Apply pipe joint sealant lightly to male NPT
threads. This will prevent excess sealant from
going into pipe. Excess sealant in pipe could
result in clogged fireplace valves. Never use
sealant on flare threads.

WARNING: Use pipe joint

sealant that is resistant to liquid

petroleum (LP) gas.

We recommend that you install a sediment
trap in supply line as shown in Figure .
Locate sediment trap where it is within reach
for cleaning. Install in piping system between
fuel supply and fireplace. Locate sediment
trap where trapped matter is not likely to
freeze. A sediment trap traps moisture and
contaminants. This keeps them from going
into fireplace gas controls. If sediment trap
is not installed or is installed wrong, fireplace
may not run properly.

INSTALLATION

Continued

Figure 22 - Gas Connection

* Purchase the optional CSA design-certified
equipment shutoff valve from your dealer. See
Accessories, page 30.
** Minimum inlet pressure for purpose of input
adjustment.

Sediment Trap

CSA Design-Certified
Equipment Shutoff Valve
With 1/8" NPT Tap*

3" Minimum

Cap Pipe Tee

Nipple Joint

Natural Gas
From Gas Meter
(5" W.C.** to
10.5" W.C. Pressure)
Propane/LP
From External
Regulator
(11" W.C.** to
14" W.C.
Pressure)

CONNECTING FIREpLACE TO GAS
SUppLY

Installation Items Needed
• 5/16" hex socket wrench or nut-driver
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not

provided)

1. Remove fireplace screen. Remove two

screws that hold fireplace screen in place
for shipping. These screws are located
near top of screen. Discard screws. Lift
fireplace screen up and pull out to re-
move.

. Remove screws that attach log base as-

sembly to fireplace (see Figure 23, page
16). Carefully lift up log base assembly
and remove from fireplace (see Figure
23, page 16).

Note: If adding the G8005 series brick liner
accessory, install it now. Follow instructions
in G8005 accessory kit.

CAUTION: Do not pick up

log base assembly by burner.

This could damage burner. Only

handle base by grates.