Continued

pOSSIBLE CAUSE

1. Control knob not fully

pressed in

. Control knob not pressed in

long enough

3. Equipment shutoff valve not

fully open

4. Pilot flame not touching

thermocouple, which allows
thermocouple to cool, caus-
ing pilot flame to go out. This
problem could be caused by
one or both of the following:

A) Low gas pressure
B) Dirty or partially clogged

ODS/pilot

5. Thermocouple connection

loose at control valve

6. Thermocouple damaged
7. Control valve damaged

1. Inlet gas pressure is too

low

2. Burner orifice(s) clogged

3. Thermopile leads disconnect-

ed or improperly connected

4. Burner will not come on in

remote position

1. Manifold pressure is too

low

2. Burner orifice(s) clogged

1. Burner orifice is clogged or

damaged

. Damaged burner
3. Gas regulator defective

1. Not enough air

. Gas regulator defective
3. Residues from manufac-

turing processes and logs
curing

REMEDY

1. Press in control knob fully

2. After ODS/pilot lights, keep

control knob pressed in 30
seconds

3. Fully open equipment shut-

off valve

4. A) Contact local natural or

propane/LP gas company


B) Clean ODS/pilot (see

Cleaning and Maintenance,
page 5) or replace ODS/
pilot assembly

5. Hand tighten until snug,

then tighten 1/4 turn more

6. Replace pilot assembly
7. Replace control valve

1. Contact local natural or

propane/LP gas company

. Clean burner(s) (see Cleaning

and Maintenance, page 25)
or replace burner orifice(s)

3. Reconnect leads (see Wir-

ing Diagram, page 30)

4. Replace battery in transmit-

ter and receiver

1. Contact local natural or

propane/LP gas company

. C l e a n b u r n e r ( s ) ( s e e

Cleaning and Maintenance,
page 5) or replace burner
orifice(s)

1. Clean burner (see Cleaning

and Maintenance, page 25)
or replace burner orifice(s)

. Replace damaged burner
3. Replace gas regulator

1. Check burner for dirt and

debris. If found, clean
burner (see Cleaning and
Maintenance
, page 25)

. Replace gas control
3. Problem will stop after a few

hours of operation

OBSERvED pROBLEM

ODS/pilot lights but flame
goes out when control knob
is released

Burner does not light after
ODS/pilot is lit

Delayed ignition of one or
both burners

Burner backfiring during
combustion

Slight smoke or odor during
initial operation