13. Do not operate fireplace if any log is

broken. Do not operate fireplace if a log
is chipped (dime-sized or larger).

14. Turn fireplace off and let cool before

servicing. Only a qualified service person
should service and repair fireplace.

15. Operating fireplace above elevations of

4,500 feet could cause pilot outage.

16. To prevent performance problems in

propane/LP units, do not use propane/
LP fuel tanks of less than 100 lbs. ca-
pacity (propane/LP units only).

17. Provide adequate clearances around air

openings.

PRODUCT

IDENTIFICATION

Figure 1 - Log Base Assembly

Piezo
Ignitor

Optional
Remote
Control

Control
Knobs

Firebox
Hood

Firebox
Support

Log Set (VYGF shown)

Remote Selector
Switch (Optional)

Top Outer
Casing

Blower Assembly
(Optional)

Screen
Assembly

Figure 2 - Fireplace

Louver

3. If you smell gas

• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do

not use any phone in your building

• immediately call your gas supplier from

a neighbor’s phone. Follow the gas
supplier’s instructions

• if you cannot reach your gas supplier,

call the fire department

4. This fireplace shall not be installed in a

bedroom or bathroom.

5. Do not use this fireplace as a wood-burn-

ing fireplace. Use only the logs provided
with the fireplace.

6. Do not add extra logs or ornaments such

as pine cones, vermiculite or rock wool.
Using these added items can cause soot-
ing. Do not add lava rock around base.
Rock and debris could fall into the control
area of fireplace.

7. To prevent the creation of soot, follow the

instructions in Cleaning and Maintenance,
page 5.

8. Before using furniture polish, wax, carpet

cleaner or similar products, turn heater off.
If heated, the vapors from these products
may create a white powder residue within
burner box or on adjacent walls or furni-
ture.

9. This fireplace needs fresh air ventilation to

run properly. This fireplace has an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the fireplace
if enough fresh air is not available. See Air
for Combustion and Ventilation,
page 6. If
fireplace keeps shutting off, see Trouble-
shooting,
page 6.

10. Do not run fireplace

• where flammable liquids or vapors are

used or stored

• under dusty conditions

11. Do not use this fireplace to cook food or

burn paper or other objects.

12. Do not use fireplace if any part has been

exposed to or under water. Immediately
call a qualified service technician to in-
spect the fireplace and to replace any part
of the control system and any gas control
which has been under water.

Advertising