Troubleshooting – Desa FPVF33NRA User Manual

Page 29

Advertising
background image

www.desatech.com

113109-01D

9

WARNING: If you smell gas

• Shut off gas supply.

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your

building.

• Immediately call your gas supplier from a neighbor’s phone. Fol-

low the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,
etc., create fumes. These fumes may mix with combustion air and create odors. These odors
will disappear over time.

pOSSIBLE CAUSE

1. Heater burning vapors from

paint, hair spray, glues,
cleaners, chemicals, new
carpet, etc. (See IMPOR-
TANT
statement above)

. Low fuel supply (propane/

LP only)

3. Gas leak. See Warning

statement at top of page

1. Not enough fresh air is

available

. Low line pressure

3. OD S/pil ot i s p arti al ly

clogged

1. Gas leak. See Warning

statement at top of page

. Control valve or gas control

defective

1. Foreign matter between

control valve and burner

. Gas leak. See Warning

statement at top of page

1. Improper log placement

. Drafts or other air currents

affecting flame pattern

3. Air holes at burner inlet

blocked

4. B u r n e r f l a m e h o l e s

blocked

REMEDY

1. Open window to venti-

late room. Stop using odor
causing products while
heater is running

2. Refill supply tank (propane/

LP only)

3. Locate and correct all leaks

(see Checking Gas Con-
nections
, page 15)

1. Open window and/or door

for ventilation

. Contact local natural or

propane/LP gas company

3. Clean ODS/pilot (see

Cleaning and Maintenance,
page 4)

1. Locate and correct all leaks

(see Checking Gas Con-
nections
, page 16)

. Replace control valve or

gas control

1. Take apart gas tubing and

remove foreign matter

. Locate and correct all leaks

(see Checking Gas Con-
nections
, page 16)

1. Properly locate logs (see

Installing Logs, page 17)

. Eliminate source of drafts

around heater

3. Clean out air holes at burner

inlet. Periodically repeat as
needed

4. Remove blockage

OBSERvED pROBLEM

Fireplace produces unwant-
ed odors

Fireplace shuts off in use
(ODS operates)

Gas odor even when control
knob is in OFF position

Gas odor during combustion

Dark residue on logs inside
of their fireplace Note: Af-
ter removing all causes of
residue deposits, completely
clean fireplace and appliance
off residue before reusing
appliance

TROUbLEShOOTING

Continued

Advertising