3. Keep control knob pressed in for 30

seconds after lighting pilot. After 30
seconds, release control knob. Now
follow steps 9 through 11 under Light-
ing Instructions
, page 20.

OpTIONAL HAND-HELD

REMOTE OpERATION

Note: All remote control accessories must
be purchased separately (see Accesso-
ries
, page 30). Follow instructions included
with the remote control.

NOTICE: You must light the pilot

before using the hand-held re-

mote control unit. See Lighting

Instructions on page 20 .

After lighting, let pilot flame burn for about
one minute. Turn control knob to ON posi-
tion. Adjust flame adjustment knob any-
where between HI and LO. Slide the selector
switch to the REMOTE position (see Figure
41). Note:
The burner may light if hand-
held remote was on when selector switch
was last turned off. You can now turn the
burner on and off with the hand-held remote
control unit.
IMPORTANT:
Do not leave the selector
switch in the REMOTE or ON position
when the pilot is not lit. This will drain
the battery.

ON/OFF SERIES (MODEL HRC100)

Hold the control button on the hand-held
remote until burner turns on. Hold the
control button again until burner turns off
(see Figure 42).

O

FF

PILO

T

ON

L O

IH

AUTO
ON
OFF

Figure 41 - Setting the Selector Switch,

Control Knob and Flame Adjustment

Knob for Remote Operation

Selector Switch in Remote
Position (Optional Hand-
Held Remote Control)

Control Knob
in On Position

Flame Adjustment Knob

Figure 42 - On/Off Hand-Held Remote

Control Unit (HRC100)

Control
Button Turns
Burners On
and Off

TO LOCK press both buttons on hand-held
remote control until light stops flashing.
Hand-held remote control is now locked. If
the fire is on it will be turned off automati-
cally. In the locked state, the light will not
light up when any button is pressed.
TO UNLOCK press both buttons together
on hand-held remote control until the light
stops flashing. The hand-held remote is
now unlocked.

THERMOSTAT SERIES (MODEL
HRC200)

The hand-held remote can be operated
using either the manual mode (MANU) or
thermostatic mode (AUTO) (see Figure
43). To select Fahrenheit/Centigrade mode
display, carefully press the ˚C/˚F mode but-
ton with the end of a paper clip or similar
blunt object.

Manual Mode
1. Press the POWER and LOCK buttons

together to turn on the hand-held remote
control.

2. Press the MANU button to turn on the

fireplace.

3. Press the POWER and LOCK buttons

together to turn off the fireplace.

Auto (Thermostatic) Mode
1. Press the POWER and LOCK buttons

together to turn on the hand-held remote
control.

2. Press AUTO button to select this mode.
3. Set the desired room temperature by

pressing the TEMP + or - buttons.

4. Press the POWER and LOCK buttons

together to turn off the fireplace