Installation Items Needed
Before installing fireplace, make sure you
have the items listed below.
• external regulator for propane/LP unit only

(supplied by installer)

• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap (optional)
• tee joint
• pipe wrench
• approved flexible gas line with gas con-

nector (if allowed by local codes) (not
provided)

* A CSA design-certified equipment shutoff
valve with 1/8" NPT tap is an acceptable al-
ternative to test gauge connection. Purchase
the optional CSA design-certified equipment
shutoff valve from your dealer. See Acces-
sories
, page 30.
For propane/LP units, the installer must
supply an external regulator. The external
regulator will reduce incoming gas pressure.
You must reduce incoming gas pressure to
between 11" and 14" of water. If you do not re-
duce incoming gas pressure, heater regulator
damage could occur. Install external regulator
with the vent pointing down as shown in Figure
1. Pointing the vent down protects it from
freezing rain or sleet.

Figure 21 - External Regulator on

Propane/LP Supply Tank with Vent

Pointing Down

External
Regulator

Vent
Pointing
Down

Propane/LP
Supply Tank

Figure 20 - Minimum Mantel Clearances

for Built-In Installation

Supplied
Firebox
Hood
Must Be
Used at
All Times

Wire-mesh
Screen

Firebox

Noncombustible
Material May
Project Off this
Surface above
the Firebox
Hood

Mantel Shelf

13" 16" 19" 21"

2

1/2

"

6"

8"

10"

Note: All vertical
measurements are
from top of fireplace
hood opening to
bottom of mantel
shelf. These minimum
clearances replace any
other recommended
clearances supplied
with your ANSI Z21.11.2
approved gas logs.

Wall board or facing
material (above
firebox) may be of
combustible material,
including decorative
mantel ornaments or
other similar projec-
tions off of the facing
material.

Framing
Material

INSTALLING GAS pIpING TO
FIREpLACE LOCATION

WARNING: This appliance

requires a 1/2" NPT (National

Pipe Thread) inlet connection to

the pressure regulator.

WARNING: A qualified

service person must connect

fireplace to gas supply. Follow

all local codes.

CAUTION: Never connect pro-

pane/LP fireplace directly to the

propane/LP supply. This fireplace

requires an external regulator

(not supplied). Install the external

regulator between the fireplace

and propane/LP supply.

WARNING: Never connect

natural gas fireplace to private

(non-utility) gas wells. This gas

is commonly known as well-

head gas.

INSTALLATION

Continued