12 close the top cover of the vivo! touch, Cleaning excess adhesive from the image belt, 3 open the top cover of the vivo! touch – QuickLabel Vivo! Touch User Manual

Page 117

Advertising
background image

Maintenance

Vivo! Touch User Guide

103

12

Close the top cover of the Vivo! Touch.

13

Reconnect the AC power cord to an earth grounded AC receptacle.

Cleaning Excess Adhesive from the Image Belt

1

Turn the printer power off and wait for the LED near the touchscreen to turn
amber. Then unplug the AC power cord from the receptacle.

2

Ensure you have a dark area ready for storing image drums during this procedure.

Caution: Image drums are sensitive to light. Never expose image drums to light for more
than five minutes and never expose the image drum to direct sunlight. Avoid contact with
the green drum inside the image drum unit.

3

Open the top cover of the Vivo! Touch.

4

Grasp the top center area of the image drum and lift it, complete with its toner
cartridge, up and out of the printer.

Place the image drum assembly on a piece of paper to avoid marking your surface
with toner. Store the assembly away from light. Repeat this process for the
remaining image drums.

Advertising