Installation instructions for qualified personnel

Important points prior to
installation

Minimum clearances

Observe the minimum clearances
to allow access for maintenance
repair work and for optimum air
distribution.

Minimum clearances

200

120

1500

120

120

All values in mm

Connection variations

The following connection
variations for the refrigerant,
condensation and control lines can
be utilized.

Connection variations

1 Outlet on the wall, right
2 Outlet through the wall, right
3 Outlet through the wall, left
4 Outlet on the wall, left

1

2

3

4

For installation of the entire
system, observe the operating
instructions of the indoor unit and
the outdoor unit.

Transport the unit in its original
packaging as close as possible
to the installation location. This
avoids transportation damage.

Check the contents of the
packaging for completeness
and check the unit for visible
transport damage.
Immediately notify any
deficiencies to the contractual
partner and forwarding agent.

Lift the unit at the corners
and not by the refrigerant or
condensation connections.

The refrigerant pipes
(injection and suction pipe),
valves and connections to make
them tight against vapour
diffusion. If necessary, also
insulate the condensation pipe.

Select an installation location
which allows air to freely
flow through the inlet and
outlet (see section "Minimum
clearances")

Do not install the unit in
the immediate vicinity of
devices with intensive thermal
radiation. Installation near
sources of thermal radiation
reduces the output of the unit.

Seal off open refrigerant pipes
with suitable caps or adhesive
strips to avoid the infiltration
of moisture and never kink or
compress the refrigerant pipes.

Only use the union nuts for the
refrigerant pipes included in
the delivery, and remove them
shortly before connecting the
refrigerant pipes.

Establish all electrical
connections in accordance with
the relevant DIN- and VDE
standards.

See electrical connection
diagram Ensure the electrical
cables are properly connected
to the terminals, otherwise
there is a risk of fire.

Installation material

The indoor unit is fastened using
4 threaded rods (provided by the
customer) over a wall brace.

Selection of the installation
location

The indoor unit is designed for
horizontal wall installation above
doors.
However, it can also be used in
the upper wall area (min. 1.75 m
above the floor).