Electrical connection diagram

Electrical circuit diagram

RXW 261 to 681

Connection RXM 226 to 435

Connection RXS 261H to 681H

Outdoor component

Indoor unit

Mains cable

Neutral conductor

Phase conductor

Earth conductor

230 V~,
50 Hz,
L1 / N
/ PE

Control conductor

Compressor contactor

N

L1

PE

L

N

1

PE

N

L

PE

3

Commissioning

Commissioning should only be
performed by specially trained
personnel and documented
after the certificate has been
issued.

Observe the manuals
for the indoor unit and
outdoor component when
commissioning the entire
system.

NOTE

Functional test for
cooling mode.

1. Switch the supply voltage on.

2. Use the remote control to

turn on the unit and select
the cooling mode, maximum
fan speed and lowest target
temperature.

3. Measure and record all

the required values in the
commissioning report and
check the safety functions.

4. Check the control system

for the unit using the
functions described in the
chapter "Operation". Timer,
temperature setting, fan speeds
and changing to ventilation or
dehumidification mode.

5. Check the correct function

of the condensation pipe by
pouring distilled water into the
condensation tray.
A bottle with a spout is
recommended for pouring the
water into the condensation
tray.

3

1

2

L

N

AC-N

FM

SM

EXF

4WV

AC-L

COMP

Outdoor component

Indoor unit

Mains cable

Neutral conductor

Phase conductor

Reverse flow valve

230 V~,
50 Hz,
L1 / N
/ PE

Control conductor

Compressor contactor

N

L1

PE

L

N

3

2

3

N

L

2

1

PE

1

PE

Control conductor

Control conductor

Earth conductor

Fan motor

front terminal block

Colour code

WH = white
BU = blue
BN = brown

Display

Receiver

circuit board

Sensor

Vaporiser

Sensor

Air circulation

Vaporiser

fan motor

Swing motor

Transformer

Phase conductor

Neutral conductor

Earth conductor

Liquefier fan

Reverse flow valve

Compressor

REMKO RXW

20