Continuous recording (cont rec), 5 − recording – Teac CD-RW901MKII User Manual

Page 32

Advertising
background image

32

TASCAM CD-RW901MKII

5 − Recording

Continuous recording (CONT REC)

Using two CD-RW901MKII units to make continuous recording.

1 Connect two CD-RW901MKII units using the

PARALLEL

ports.

Unit 1

Unit 2

EOM TALLY (pin 5)

FADER START/STOP

(pin 11)

FADER START/STOP

(pin 11)

EOM TALLY (pin 5)

GND (pin 8)

GND (pin 8)

2 On both units, select the CONT REC sub-menu in

the REC option (see “Operation basics” on page 16).

Cont Rec> XXX

appears on the display where

XXX shows time setting of 30s, 60s or 90s to trigger

the units to start recording when the EOM (End of

Message) tally signal is received one after another.

NOTE

OFF is also shown in the time setting, however if
selected, the CONT REC function is canceled.

We recommend selecting the same time setting on
both units.

The CD-RW901MKII may take longer for OPC calibra-
tion for discs with scratches, grime or dust. To avoid
clipping a recording, we recommend not to use such
discs, or to select a time setting more than 30s.

3 Connect recording source(s) to both units.
4 Press

REC

key on the one of the units to start

continuous recording, and

Cont Rec

lights up in

the display.

While the one unit is recording, the second unit

should be in stop mode.

When the remaining time on a disc being recorded

reaches the time setting, the unit sends the EOM

tally signal to the second unit.

Simultaneously,

Now OPC

is displayed on the second

unit, and when OPC calibration completes, the unit

starts recording.

The two units are now in recording mode during

the time setting selected.

When the first unit finishes recording, the recorded disc

should be replaced with another recordable disc for the

next recording which starts when the unit receives the EOM

tally signal from the second unit. This loop recording will be

continued until either of the units is stopped.

NOTE

While the first unit is recording, the second unit can
be set in recording standby mode. However, it may
shorten the unit’s lifetime by running the motor
continuously. We recommend to set the second unit in
stop mode during stand by.

If the number of tracks is restricted, the EOM tally
signal is not output and the continuous recording
cannot be operated.

The CONT REC function remains selected even the
power is turned off, so that when the power is turned
on again on one of the units, and when the following
conditions are met, the unit starts recording:

Both units are connected

The unit has a recordable disc

To avoid recording accidently, remove the recordable
disc from the unit before turning off the power, or
disconnect the units from each other.

Use two CD-RW901MKII units connected only when
CONT REC is operated. In any other operation, two
units should be disconnected, or set the CONT REC
function off on both units to avoid any unexpected
recording.

Advertising