Hs-4000, Ethernet page added to the remote setup screen, Field selected dhcp static – Teac HS-4000 Addendum V1.22 User Manual

Page 7

Advertising
background image

X

HS-4000

TASCAM HS-4000

7

ETHERNET page added to the REMOTE SETUP screen

Use this to make settings related to Ethernet communication.

STATUS

This shows the unit's MAC Address and current IP Address.

IP MODE

Use these buttons to enable or disable Ethernet functions.

Setting buttons:

Disable

(default value),

Enable

IP SETUP

Use to switch between

DHCP

and

STATIC

.

When set to

DHCP

, and there is a DHCP server on the LAN, the

IP

Address

,

Subnet

Mask

and

Default

Gateway

items should be automatically

acquired.
When set to

STATIC

, you must set the

IP

Address

,

Subnet

Mask

and

Default

Gateway

items manually.

Setting buttons:

DHCP

,

STATIC

(default value)

LINK SPEED

Use these buttons to set the link speed.

Setting buttons:

AUTO

(default value automatically adjusts speed

according to connection),

100M

(operates with fixed speed of 100 Mbps.)

IP Address/Subnet Mask/Default Gateway

These show the current values of these settings. When

IP

SETUP

is set to

STATIC

, use these field to set the values.

Default values: 0. 0. 0. 0

Depending on the

IP

SETUP

setting, this area appears differently as shown

below.

IP Address/Subnet Mask/Default Gateway editing screen

Touch the corresponding area of the

REMOTE

SETUP

screen

ETHERNET

page

to open its value setting screen.

Each field can contain up to 3 digits. (You do not need to input "0"

i

before values of 1–2 digits.)

The first field is selected when a screen opens.

i

After a field is selected, touching a number button will enter that digit.

i

When touched, further digits will be added to the end of the same

field.

Touch the period (point) button to move to the next field.

i

Example

Screen opened 192.

168. 1.

1

"1234" input 234.

168. 1.

1

(First "1" is discarded)

"." input

192.

168.

1.

1

CHANGE PASSWORD screen

Touch the

Change

button in the

Password

section of the

REMOTE

SETUP

screen

ETHERNET

page to open the

CHANGE

PASSWORD

screen where you

can set the password.

Up to 9 characters can be used.

Field selected

DHCP

STATIC

Advertising