Port usage, Adapter cables, Port usage -6 adapter cables -6 – Verilink NCC 2130 (880-503285-001) Product Manual User Manual

Page 14

Advertising
background image

Overview

1-6

Verilink NCC 2130 User Manual

Port Usage

Table 1-3

describes the usage of the ports on the various rear

connector modules (CDMs) used with the NCC 2130 front module.

Table 1-3

NCC 2020 Connector Ports

Adapter Cables

Because of the limited space on the rear connector modules, a mini
D-Sub 26-pin connector is used for the data port connection in all
cases. A short adapter cable is also provided. This adapter cable,
sometimes called a pigtail cable, presents the typical connector for
the specific electrical interface. See

Table 1-4

for a cross reference

of these adapter cables.

Table 1-4

Adapter Cables Used With NCC 2130

Port

Located

Usage

Craft

Front

Connect ASCII terminal for configuration, diagnostics, alarm monitoring,

and/or performance monitoring.

Bantam Jacks

Front

The bantam jacks on the NCC 2130 will never reflect actual signals on the T1

circuit. Do not use these bantam jacks.

Network

Rear

Connect the T1 line to this port.

Data

Rear

Connect the supplied adapter cable, which in turn connects to the customer

data equipment. The DTE must support the synchronous serial interface type

for which the selected CDM is designed.

Management

Port In

Rear

Connect directly to a node management PC or to a modem for dialup to a PC

running either of the Verilink management programs — Access Manager 2000

or Node Manager.

Management

Extension

Rear

Connect a cable to an additional node at the same location. This feature is

only supported when Access Manager 2000 is used for node management.

Ext Timing

Rear

Connect an optional external clock source, using either a TTL level (0 to +5V)

or balanced (RS-422) signal. The clock must be at 1.544 Mbit/s.

Alarm Relay

Rear

Connect an external alarm system which will trigger on either a relay closure

(using NO and COM leads) or open (using NC and COM leads). The relay in the

NCC module supports Form C relay specifications.

Cable p/n

Electrical

Interface

Used With CDM Types

Connectors

458-501594-001

ITU V.35

CDM 2035, CDM 2135

Mini D-Sub 26 - Winchester 34-pin

458-502059-001

RS-449

(RS-422)

CDM 2049; CDM 2149

Mini D-Sub 26 - DB-37

458-502045-001

EIA 530

CDM 2049; CDM 2149

Mini D-Sub 26 - DB-25