Varmeca - 20, Variable speed motor or geared motor – Watson-Marlow Varmeca User Manual

Page 25

Advertising
background image

23

INSTALLATION AND MAINTENANCE

VARMECA - 20

Variable speed motor or geared motor

GENERAL INFORMATION

LEROY-SOMER

Réf. 3481 - 4.33/c - 09.01

1.3.2 - Characteristics and functions

* Adjust using mini DIP switch (see section 2.3)
** Adjustable using parameter setting option (see VARMECA 20 parameter-setting manual).

CHARACTERISTICS

VARMECA - 20

Overload

150 % of In for 40s, 10 times per hour

Motor frequency variation range

- from 12 to 80 Hz at constant torque

- from 12 to 50 Hz for general applications
- from 6 to 220 Hz (VARMECA A20) - from 6 to 100 Hz (VARMECA B20)**

Efficiency

97.5 % x motor efficiency

PILOT CONTROL

VARMECA - 20

Speed reference

• Analogue reference

(0V or 4mA = minimum speed)

(10V or 20mA = maximum speed)

- 0 - 10V with integrated potentiometer (option B)
- 0 - 10V with remote potentiometer option
- 0 - 10V with external reference*
- 4 -20mA with external reference*
- reference with internal potentiometer (CVI - VMA 20 option)
- limitation of maximum speed with internal potentiometer (CVI - VMA 20 option)

• Digital reference

- 1 to 4 preset speeds**

• With fieldbus

Speed regulation

Regulation of a reference with the integrated PI loop** (VARMECA 20)
PI sensor characteristic: 0 - 10V or 4 - 20 mA signal*

Run/Stop

• With the power supply
• With remote volt-free contact
• With integrated Run/Stop control (BMA option)
• With fieldbus

Forward/Reverse

• With internal connection on the terminal block
• With remote volt-free contact
• With integrated Forward/Reverse/Stop control (BMAVAR option)
• With fieldbus

Stop mode

• On ramp (with volt-free contact or integrated Run/Stop control)
• Freewheel stop (by cutting the power supply)**
• Freewheel stop (with volt-free contact or integrated Run/Stop control)**
• With electromechanical brake

Ramps

• Selection of acceleration and deceleration ramps with volt-free contact: 2s or 5s

(factory setting 5s for F max 80 Hz)

• Ramps adjustable from 0 to 100s (VARMECA A20) - from 0 to 40s (VARMECA B20)**

Fieldbus

PROFIBUS DP, INTERBUS S, DEVICENET, CAN OPEN

INDICATION

VARMECA - 20

Display with options:

- B
- BMA
- BMAVAR
- CVIVMA20

With indicator lamps
• Steady green light: mains connected
• Flashing green light: overload
• Flashing green and red lights: current limit
• Flashing red light: fault, under/overvoltage
• Steady red light: other fault

Relay

• Drive fault (other assignments possible**)

volt-free contact - 1A - 250V - contact open, drive faulty or powered
down

Analogue output

• Speed signal 0 - 10V, 3mA

/ Current signal***

/

Power signal***

• 0V = zero speed

/

0V = 0A

/

0V = 0 kW

• 10V = max. speed

/

10V = 10A

/

10V = 5 kW

*** VARMECA A20**

PROTECTION

VARMECA - 20

Power

• Undervoltage
• Overvoltage
• Overloads:

- overheating, drive and motor
- protection against locked rotor

• Short-circuit

- motor windings

Torque limitation

• VARMECA B20**

Control

• Short-circuit on 0 - 10V - 24V inputs or outputs

Trip clearance

• By switching off the VARMECA

en