Interface specifications – Westermo IDW-90 User Manual

Page 12

Advertising
background image

12

6620-2200

Interface specifications

Power “LV”
Rated voltage

12 to 48 VDC
12 to 34 VAC

Operating voltage

10 to 60 VDC
10 to 42 VAC

Rated current

110 mA @ 12 VDC
55 mA @ 24 VDC
30 mA @ 48 VDC

Rated frequency

DC / AC 48 – 62 Hz

Inrush current I

2

t

0.22 A

2

s

Startup current*

0.30 A

peak

Polarity

Polarity independent

Isolation to

All other ports 3 kV

rms

50 Hz 1 min

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm

2

(AWG 24 – 12)

Shielded cable

Not required

Integrated Services Digital Network (ISDN)
Electrical specification

ISDN BRI: ITU-T I.430.

Data rate

300 bit/s – 128 kbit/s

Protocol

Euro ISDN /DSS1, Leased line B1 / B2
V.110 asynchronous, HDLC async to sync, HDLC transparent,
Byte transparent X.75- SLP, V.120, X.31 B channel, X.31
D channel, ML-PPP

Protection

Installation Fault Tolerant (up to ±60 V)

Isolation to

Power port 3 kV

rms

50 Hz 1 min

RS-232 2 kV

rms

50 Hz 1 min

RS-485 2 kV

rms

50 Hz 1 min

I/O 2 kV

rms

50 Hz 1 min

Connection

RJ-45

Shielded cable

Not required

* External supply current required for proper startup.