Westermo IDW-90 User Manual

Page 40

Advertising
background image

40

6620-2200

IDW-90

Termination

1

2

ISDN

Network

… IDW-90 two wire half duplex

In this application the IDW-90 is set to communicate with a number of units with RS-485
interface. The communication is 2 wire half duplex at 38 400 bit/s, 8 data, parity even and
1 stop bit.
Configure the IDW-90

at**defa=0at**defa=1

Set the unit to factory default

AT&W

Store default settings

S2:6 ON

RS-422/485 enable RS-232 disable

S2:7 OFF

Select 2-wire RS-485

S1:4 ON

38.4 kbit/s

S1:7 ON

8data bits even parity 1 stop bit

To make switch setting active the power must be cycled OFF -> ON.

Advertising