6620-2200

!+MS – Select Modulation for analogue connections

Syntax:
+MS=<carrier>,<automode>,<min_tx_rate>,<max_tx_rate>,<min_rx_rate>,<max_rx_rate>
+MS= ?
+MS ?

Parameters:
<carrier>
B103 300 bit/s
B212 1200 bit/s
V21 300 bit/s
V22 1200 bit/s
V22B 1200 or 2400 bit/s
V23C 1200 bit/s
V32 4800 or 9600 bit/s
V32B 4800, 7200, 9600, 12000 or 144400 bit/s
V34 2400, 4800, 7200, 9600, 12000, 14400, 16800, 19200, 21600, 24000, 26400, 28800,

31200, 33600, 33600 bit/s

<automode>
0: Disable
1: Enable
< min_xx_rate >, < max_xx_rate >
Minimum and maximum data rate depending on modulation used.

**prty – Asynchronous parity

Syntax:
AT**prty=<n>
AT**prty=?
AT**prty

Parameters:
<n>:
0:

No parity

1: Set even parity
2: Set odd parity