Grounding the router, Installing the ring terminal – H3C Technologies H3C SR6600-X User Manual
Page 21
Advertising
11
Figure 8 Installing the router to the rack
Grounding the router
Installing the ring terminal
No ring terminal is supplied with the grounding cable. You must install one yourself.
To install the ring terminal:
1.
Cut the grounding cable as appropriate for connecting to the grounding strip, and strip 5 mm
(0.20 in) of insulation sheath by using a wire stripper.
2.
Insert the bare metal part through the black insulation covering into the end of the ring terminal.
3.
Crimp the metal part of the cable to the ring terminal with a crimper.
4.
Cover the joint with the insulation covering, and heat the insulation covering with a blow dryer to
completely cover the metal part.