GUIDE TO INSTALLATION AND OPERATION

6 | 3DX-3901

3 Operation

3.1 Control

options


The 3DX-3901 can be controlled in two different ways:

• The local control panel and its push-buttons can be used to move through a menu of parameters and to adjust

parameter values (see section 3.3).

• Miranda’s iControl system can be used to access the card’s operating parameters from a remote computer,

using a convenient graphical user interface (GUI). (see section 3.4)

3.2 Card-Edge Status LED

The status monitor LED is located on the front card-edge of the 3DX-3901, and is visible through the front access
door of the DENSITÉ frame. The chart shows how the various error conditions that can be flagged on the 3DX-3901
affect the LED status.

• If a cell in the chart is gray, the error condition cannot cause the LED to assume that status
• If more than one LED status is possible for a particular error condition, the status is configurable.

See Section 3.4.8 for details.

• The factory default status is shown by a , and forced status by an X

The LED will always show the most severe detected error status that it is configured to display, and in the chart
error severity increases from left to right, with green representing no error/disabled, and flashing red the most
severe error.

Alarm Name/Error Report

LED Color

Green

Yellow

Red

Flashing

Red

No Rear Detected

X

No IN 1 carrier

No IN 2 carrier

Video Error

Reference Mismatch

If the LED is Flashing Yellow, it means that the card is selected for local control using the Densité frame’s control
panel. See Section 3.3 for details.