Configuring dolby metadata – Grass Valley iTX Output Server 2 v.2.6 User Manual
Page 42

36
Output Server 2 Channel Configuration
Configuring Dolby Metadata
7 In the Check Digit field, enter the two-letter Nielsen check digit.
8 In the Distribution Type field, select one of the following:
• Program Content
• Final Distributor
• Unknown Distribution
9 Click Save to store your changes and automatically reboot the Output Server 2 service.
Alternatively, wait until you have finished making changes in other areas of the
Configuration panel, then click Save.
Configuring Dolby Metadata
Dolby metadata can be configured for Dolby E and Dolby D output groups using the Dolby
Metadata tab. During configuration, you can set specific values for each parameter and set
a resolution rule.
Setting the Rule field to Manual Value applies the set value as the constant default.
Setting the Rule field to Decoders, then manual value applies a conditional setting such
that if the Dolby decoder provides a setting for that metadata parameter, then the
decoder’s setting takes precedent over the set value.
To configure metadata for Dolby E and/or Dolby D output groups:
1 Open the Output Server 2 user interface for the channel you want to configure, as
described in
Accessing the Output Server 2 User Interface
2 Go to Configuration > Dolby Metadata tab.
The Dolby metadata configuration options appear.