JEP Series — Installation Manual
Section 2 — JEP-100 CP Operation
Figure 41. Levels and Sequences CP Sets
Password Protection
A password level below 90 then a operator cannot:
•
Assign sources destinations, levels, or salvos to buttons.
•
Change the Id of the panel
•
Change the connection type of the panel.
The menu items “change ID” and “ES Lan on/off” will not be visible to the
user.
A password level that is less than 95:
•
The button assignment will be enabled
•
The user cannot change the connection type, or the panel ID.
A password level of 95 or greater:
The button assignment is enabled and the operator can change the connec-
tion type and the panel ID from the menu of the control panel.
Setting Password Protection
Follow these steps to disable the Configuration and Setup menus on the
Control panel:
1.
Open the MPK Devices table.
CP3800 Type