Power led, Service led – Grass Valley K2 Summit 3G v.8.0 User Manual

Page 35

Advertising
background image

Power

LED

Standby

switch

Service

LED

Power LED

The Power LED indicates status as follows::

Status Condition

LED behavior

The standby switch is set to Off and the K2 Summit 3G system is not
operational.

Off

The standby switch is set to On and the K2 Summit 3G system is either in
the startup process or has completed the startup process and is operational.

Green steady on

WARNING: The power standby switch does not turn off power to the system. To turn power off both
power supplies must be disconnected from the power source.

Service LED

The following table explains the status conditions indicated by the different Service LED behaviors.
If two or more status conditions occur simultaneously, the LED displays the behavior for the highest
priority condition.

Priority

Status Condition

LED behavior

1

Identify — The K2 Summit system is being directed
to identify itself by NetCentral or some other
application.

Flashing pattern alternating
Yellow/Green/Red/Off twice a
second

2

Global failure — The K2 Summit system software
has detected a critical error or failure that impacts
record/play operations.

Solid Red

3

Warning — The K2 Summit system software has
detected a problem that requires attention but does
not immediately impact record/play operations. For
example, a fan or power supply has failed but its
redundant partner is maintaining functionality.

Solid Yellow

4

Drive failure — An internal RAID drive has failed.
If RAID 1, the failure does not immediately impact
record/play operations. The redundant partner RAID
drive is maintaining functionality.

Flashing Yellow pattern three times
a second.

5

Drive rebuild — If RAID 1, an internal RAID drive
is rebuilding.

Flashing pattern alternating
Yellow/Green once a second.