Corrective Actions
Possible Causes
Problem
Check for thermal problems.
Cool the K2 Summit system.
The K2 Summit system is too
hot. The built-in
overtemperature protection can
shut down the power supply.
Replace the power supply.
The power supply is faulty. This
is indicated if the front panel
power indicator does not come
on.
Check for and remove any air
flow blockage around the power
supply.
Over temperature due to air flow
restriction.
Power supply “~AC” LED is
amber
Visually inspect fan. Listen for
fan noise. If faulty, replace
power supply.
Over temperature due to power
supply fan failure.
Disengage all FRU modules,
then re-engage one at time. If
one module causes the amber
LED to go on, replace the
module. If both power supplies
have the amber LED, disengage
one, then the other. If doing so
results in just one power supply
having the amber LED, replace
that power supply.
Over current, under voltage,
over voltage. These conditions
could be caused by a faulty FRU
module.
Related Topics
on page 102
Video problems
For the corrective actions in this section, refer to related topics in "K2 AppCenter User Manual" for
detailed instructions.
Corrective Actions
Possible Causes
Problem
Check the video input signal for
distortion. Compare with test
color bars and audio test tone.
There is distortion in the video
input signal.
The picture level modulates at
a particular frequency.
Switch the still-play mode
setting to Field.
Two fields are displayed in still
play mode.
In stop mode the still-play
video shows some motion jitter.
Lock the K2 Summit system to
a video reference.
K2 Summit system is not locked
to a video reference.
The video displays erratically
moving green lines.
88
K2 Summit 3G Production Client Service Manual
02 February 2012
Troubleshooting problems