Abbreviations used:
IF
If
EQU
Equals
NE
Not equal
GT
Greater than
LT
Less than
GOTO
Go to
10.6 Checking and Changing
Q Parameters
During a program run or test run, you can check or change Q
parameters if necessary.
ú
If you are in a program run, interrupt it (for example by pressing
the machine STOP button and the STOP soft key). If you are doing
a test run, interrupt it.
ú
To call the Q parameter table, press the Q key.
ú
Using the arrow keys you can select a Q-parameter on
the current screen page. You can go to the next or the
previous screen page using the PAGE soft keys.
ú
If you wish to change the value of a parameter, enter a
new value, confirm it with the ENT key and conclude
your entry with the END key.
To leave the value unchanged, terminate the dialog
with the END key.