HEIDENHAIN TNC 410 User Manual
Page 236

223
HEIDENHAIN TNC 410
1
0
.9
Pr
eassigned Q P
a
ra
met
ers
Unit of measurement for dimensions in the program: Q113
The value of parameter Q113 specifies whether the highest-level
NC program (for nesting with PGM CALL) is programmed in
millimeters or inches.
Dimensions of the main program
Parameter value
Metric system (mm)
Q113 = 0
Inch system (inches)
Q113 = 1
Tool length: Q114
The current value for the tool length is assigned to Q114.
Coordinates after probing during program run
The parameters Q115 to Q118 contain the coordinates of the
spindle position at the moment of contact during programmed
measurement with the 3-D touch probe.
The length and radius of the probe tip are not compensated in
these coordinates.
Coordinate axis
Parameter
X axis
Q115
Y axis
Q116
Z axis
Q117
IVth axis
Q118
Deviation between actual value and nominal value during
automatic tool measurement with the TT 120
Actual-nominal deviation
Parameter
Tool length
Q115
Tool radius
Q116
Active tool radius compensation
Active radius compensation
Parameter value
R0
Q123 = 0
RL
Q123 = 1
RR
Q123 = 2
R+
Q123 = 3
R–
Q123 = 4