1 gener al user p a ra met ers – HEIDENHAIN TNC 410 User Manual
Page 299

15 Tables and Overviews
286
15.1 Gener
al User P
a
ra
met
ers
Reset status display, Q parameters and tool data at program end
MP7300
Do not delete status display: +0
Delete status display: +1
Delete Q parameter: +0
Do not delete Q parameter: +2
Delete tool number, axis and data: +0
Do not delete tool number, axis and data: +4
Graphic display mode
MP7310
Projection in three planes according to ISO 6433, projection method 1: +0
Projection in three planes according to ISO 6433, projection method 2: +1
Do not rotate coordinate system for graphic display: +0
Rotate coordinate system for graphic display by 90°: +2
Simulation for fixed cycles, draw only the last infeed: +0
Simulation for fixed cycles, draw all infeeds: +16
Programming graphic display mode
MP7311
Do not show penetration points as circle: +0
Show penetration points as circle: +1
Do not show meander paths in cycles: +0
Show meander paths in cycles: +2
Do not show compensated paths: +0
Show compensated paths: +3