6.5.3 Connecting DC Main Cables to the Terminals

The terminals are available as accessories.

Mounting Terminals to the Busbar

Figure 13: Connection of terminals to busbars

Additionally required material:

☐ Ethanol cleaning agent
☐ Clean cloth

Procedure:

1. Wipe the contact surfaces on the busbar and the terminal with a clean cloth and ethanol cleaner. Do not touch the

surfaces once they have been cleaned.

2. Mount the terminals on the busbar (torque: 60 Nm). Only use the supplied screws, nuts and washers and make sure

that the screw heads always point backwards.

Connecting Copper Cables to the Terminals

1. Strip off the DC main cable insulations by 35 mm.
2. Connect the DC main cables to the terminals:

• Unscrew the set screw with an Allen key.
• Insert the DC main cables into the terminal from below. Ensure correct polarity.
• Fasten the set screw (torque: 32 Nm).

3. Ensure that the DC main cables are securely in place.

Position

Designation

A

Screw M12

B

Spring washer

C

Fender washer

D

Tin-plated copper bar

E

Terminal

F

Nut M12