9 fault diagnosis and possible solutions – Yaskawa 1000 Series Drive Option - CANopen Installation User Manual

Page 34

Advertising
background image

9 Fault Diagnosis and Possible Solutions

34

YASKAWA ELECTRIC TOBP C730600 45B 1000-Series Option SI-S3 Installation Manual

Digital Operator Display

Fault Name

oFb00

Option Card Fault at Connector CN5-B
Non-compatible option card is connected.

Cause

Possible Solution

The CANopen option card has been
plugged into option port CN5-B.

⇒ Always use option port CN5-A for communication option cards.

Digital Operator Display

Fault Name

oFb02

Option Card Fault at Connector CN5-B
Two of the same option cards are connected at the same time.

Cause

Possible Solution

Two or more input option cards
(analog, digital or communication)
have been connected to the drive at the
same time.

⇒ Use either an analog input option AI-A3 or a digital input option DI-A3
or a communication option card. Never use two of these cards at the same
time.

Digital Operator Display

Fault Name

oFC00

Option Card Fault at Connector CN5-C
Non-compatible option card is connected.

Cause

Possible Solution

The CANopen option card has been
plugged into option port CN5-C.

⇒ Always use option port CN5-A for communication option cards.

Digital Operator Display

Fault Name

oFC02

Option Card Fault at Connector CN5-C
Two of the same option cards are connected at the same time.

Cause

Possible Solution

Two or more input option cards
(analog, digital or communication)
have been connected to the drive at the
same time.

⇒ Use either an analog input option AI-A3 or a digital input option DI-A3
or a communication option card. Never use two of these cards at the same
time.

Advertising
This manual is related to the following products: