7 Option Data and I/O Maps

YASKAWA ELECTRIC TOBP C730600 42C 1000-Series Option SI-P3 Installation Manual

29

Supported Parameter Process Data Object (PPO) Type Formats

Set drive parameter F6-32 to 0 to use PPO type formats. The PPO is defined for cyclic data

transfer, allowing the master and the slave to exchange process data (PZD) and parameters.

Refer to the PROFIBUS specification for more information on PPO types 1~5.
The option supports five possible PPO type formats:

• PPO type 1 (8 octets PKW + 4 octets PZD)

• PPO type 2 (8 octets PKW + 12 octets PZD)

• PPO type 3 (4 octets PZD)

• PPO type 4 (12 octets PZD)

• PPO type 5 (8 octets PKW + 20 octets PZD)

All PPO Types have the registers STW, ZSW, HSW, and HIW. These registers are not

mapped directly to drive registers.

7

MEMOBUS/Modbus Data Length

7

MEMOBUS/Modbus Data Length

8

MEMOBUS/Modbus Data 1 High Byte

8

MEMOBUS/Modbus Data 1 High Byte

9

MEMOBUS/Modbus Data 1 Low Byte

9

MEMOBUS/Modbus Data 1 Low Byte

10

Reserved

10

Reserved

11

Handshaking Register

11

Handshaking Register

<1> Unit depends on the setting of o1-03 (Digital Operator Display Scaling). When the drive is operating in V/f

Control or OLV/PM, the drive output frequency becomes the input data.

Output (Master Device to Drive)

Input (Drive to Master Device)

Byte

Description

Byte

Description