5 installation procedure – Yaskawa PG-E3 Motor Encoder Feedback User Manual

Page 18

Advertising
background image

5 Installation Procedure

YASKAWA ELECTRIC TOBP C730600 52C 1000-Series Option PG-E3 Installation Manual

17

7.

Set drive parameters for proper motor rotation.
The leading pulse determines the motor rotation direction. A PG encoder signal with

leading A pulse is considered to be rotating forward (counter-clockwise when

viewing rotation from motor load side).

Figure 10

Figure 9 Displacement of A and B Pulses

After connecting the PG encoder outputs to the option, apply power to the drive and

manually rotate the motor and check the rotation direction by viewing monitor U1-05

on the digital operator.

Reverse motor rotation is indicated by a negative value for U1-05; forward motor

rotation is indicated by a positive value.

If monitor U1-05 indicates that the forward direction is opposite of what is intended,

set drive parameter F1-05 to 1 to switch the direction of how the option reads pulses

from the PG encoder output.

Please note that when the drive is initialized using A1-03 =1110, 2220, 3330, the

value for F1-05 will reset to factory default and the parameter will need to be

adjusted again to switch the direction.

A

B

The A pulse leads, followed
by the B pulse displaced at 90 degrees

Time

Pulse

Pulse

E3

Advertising