5 Installation Procedure

20

YASKAWA ELECTRIC TOBP C730600 52C 1000-Series Option PG-E3 Installation Manual

TB2

IP

PG encoder Power Supply

Supplies power to the PG encoder.
Voltage range: 5 V

± 5%, 200 mA

A+

A Pulse Signal Input

Input for the A pulse sine-wave from the PG encoder.

• Max. input frequency: 20 kHz
• Input signal differential: A+ – A–

A–

Inverse A Pulse Signal Input

C+

C Pulse Signal Input

Input for the C pulse sine-wave from the PG encoder.
Input signal differential: C+ – C–

C–

Inverse C Pulse Signal Input

R+

R Pulse Signal Input

Input for the R pulse (PG encoder home pulse) from
the PG encoder.
Input signal differential: R+ – R–

R–

Inverse R Pulse Signal Input

a+

A Pulse Monitor Signal Output

Outputs a ratio of the A pulse frequency.

• Output method: Line driver
• Output voltage: RS-422 level
• Possible resolution:1/n

Set F1-06 to monitor the pulse signal.
Varies by drive model.

a–

Inverse A Pulse Monitor Signal
Output

Terminal

Block

Terminal

Function

Description

0.6 V to 1.2 V

0.6 V to 1.2 V

0.2 V to 2.38 V

Advertising