6 Related Parameters
YASKAWA ELECTRIC TOBP C730600 52C 1000-Series Option PG-E3 Installation Manual
23
F1-51
(3D3)
PGoH
Detection
Level
Set the level for detecting PG Hardware Fault
(PGoH). Set as a percentage of
.
CLV/PM
Default: 80
Min: 1
Max: 100
<1> Varies by drive models.
<2> The output frequency of the PG encoder can be calculated as follows:
No.
(Addr. Hex)
Name
Description
Available
Control
Mode
Values
Sin
θ
2
+ Cos
θ
2
Operation at max.
output frequency
Motor speed at maximum frequency output (r/min)
60
× PG rating (p/rev)
=