6 Related Parameters

YASKAWA ELECTRIC TOBP C730600 52C 1000-Series Option PG-E3 Installation Manual

23

F1-51
(3D3)

PGoH
Detection
Level

Set the level for detecting PG Hardware Fault
(PGoH). Set as a percentage of

.

CLV/PM

Default: 80
Min: 1
Max: 100

<1> Varies by drive models.

<2> The output frequency of the PG encoder can be calculated as follows:

No.

(Addr. Hex)

Name

Description

Available

Control

Mode

Values

Sin

θ

2

+ Cos

θ

2

Operation at max.

output frequency

Motor speed at maximum frequency output (r/min)

60

× PG rating (p/rev)

E3