7 troubleshooting, Preventing noise interference, 7troubleshooting – Yaskawa PG-E3 Motor Encoder Feedback User Manual

Page 25

Advertising
background image

24

YASKAWA ELECTRIC TOBP C730600 52C 1000-Series Option PG-E3 Installation Manual

7 Troubleshooting

7

Troubleshooting

Preventing Noise Interference

Take the following steps to prevent erroneous operation caused by noise interference:

• Use shielded wire for the PG encoder signal lines.

• Limit the length of all motor output power cables to less than 10 m.

• Separate the control wiring to the option, main circuit input power wiring, and motor

output power cables.

• Ground the shield on the PG encoder side and the drive side. If noise problems arise in the

PG encoder signal, verify that the shield is properly grounded and ground one end of the

signal line or remove the ground connection on both ends.

• Properly connect the shield in cable to the IG on the option terminal or remove the ground

connection on both ends.

Interface Circuit

Figure 11

Figure 10 Interface Circuit

PG-E3

2.5 V

2.5 V

120

Ω

1 k

Ω

A–,B–,R–

A+,B+,R+

C–,D–

C+,D+

a+

a–

b+

b–

PG Encoder

Monitor Signal

26LS31 Level

Advertising